FDA Consultant Specialist
FDA regulatory consulting for medical device manufacturers covering submission pathways, Quality System Regulation (QSR), HIPAA compliance, and device cybersecurity requirements.
Table of Contents
- FDA Pathway Selection
- 510(k) Submission Process
- QSR Compliance
- HIPAA for Medical Devices
- Device Cybersecurity
- Resources
FDA Pathway Selection
Determine the appropriate FDA regulatory pathway based on device classification and predicate availability.
Decision Framework
Predicate device exists?
โโโ YES โ Substantially equivalent?
โ โโโ YES โ 510(k) Pathway
โ โ โโโ No design changes โ Abbreviated 510(k)
โ โ โโโ Manufacturing only โ Special 510(k)
โ โ โโโ Design/performance โ Traditional 510(k)
โ โโโ NO โ PMA or De Novo
โโโ NO โ Novel device?
โโโ Low-to-moderate risk โ De Novo
โโโ High risk (Class III) โ PMA
Pathway Comparison
| Pathway | When to Use | Timeline | Cost |
|---|---|---|---|
| 510(k) Traditional | Predicate exists, design changes | 90 days | $21,760 |
| 510(k) Special | Manufacturing changes only | 30 days | $21,760 |
| 510(k) Abbreviated | Guidance/standard conformance | 30 days | $21,760 |
| De Novo | Novel, low-moderate risk | 150 days | $134,676 |
| PMA | Class III, no predicate | 180+ days | $425,000+ |
Pre-Submission Strategy
- Identify product code and classification
- Search 510(k) database for predicates
- Assess substantial equivalence feasibility
- Prepare Q-Sub questions for FDA
- Schedule Pre-Sub meeting if needed
Reference: See fda_submission_guide.md for pathway decision matrices and submission requirements.
510(k) Submission Process
Workflow
Phase 1: Planning
โโโ Step 1: Identify predicate device(s)
โโโ Step 2: Compare intended use and technology
โโโ Step 3: Determine testing requirements
โโโ Checkpoint: SE argument feasible?
Phase 2: Preparation
โโโ Step 4: Complete performance testing
โโโ Step 5: Prepare device description
โโโ Step 6: Document SE comparison
โโโ Step 7: Finalize labeling
โโโ Checkpoint: All required sections complete?
Phase 3: Submission
โโโ Step 8: Assemble submission package
โโโ Step 9: Submit via eSTAR
โโโ Step 10: Track acknowledgment
โโโ Checkpoint: Submission accepted?
Phase 4: Review
โโโ Step 11: Monitor review status
โโโ Step 12: Respond to AI requests
โโโ Step 13: Receive decision
โโโ Verification: SE letter received?
Required Sections (21 CFR 807.87)
| Section | Content |
|---|---|
| Cover Letter | Submission type, device ID, contact info |
| Form 3514 | CDRH premarket review cover sheet |
| Device Description | Physical description, principles of operation |
| Indications for Use | Form 3881, patient population, use environment |
| SE Comparison | Side-by-side comparison with predicate |
| Performance Testing | Bench, biocompatibility, electrical safety |
| Software Documentation | Level of concern, hazard analysis (IEC 62304) |
| Labeling | IFU, package labels, warnings |
| 510(k) Summary | Public summary of submission |
Common RTA Issues
| Issue | Prevention |
|---|---|
| Missing user fee | Verify payment before submission |
| Incomplete Form 3514 | Review all fields, ensure signature |
| No predicate identified | Confirm K-number in FDA database |
| Inadequate SE comparison | Address all technological characteristics |
QSR Compliance
Quality System Regulation (21 CFR Part 820) requirements for medical device manufacturers.
Key Subsystems
| Section | Title | Focus |
|---|---|---|
| 820.20 | Management Responsibility | Quality policy, org structure, management review |
| 820.30 | Design Controls | Input, output, review, verification, validation |
| 820.40 | Document Controls | Approval, distribution, change control |
| 820.50 | Purchasing Controls | Supplier qualification, purchasing data |
| 820.70 | Production Controls | Process validation, environmental controls |
| 820.100 | CAPA | Root cause analysis, corrective actions |
| 820.181 | Device Master Record | Specifications, procedures, acceptance criteria |
Design Controls Workflow (820.30)
Step 1: Design Input
โโโ Capture user needs, intended use, regulatory requirements
Verification: Inputs reviewed and approved?
Step 2: Design Output
โโโ Create specifications, drawings, software architecture
Verification: Outputs traceable to inputs?
Step 3: Design Review
โโโ Conduct reviews at each phase milestone
Verification: Review records with signatures?
Step 4: Design Verification
โโโ Perform testing against specifications
Verification: All tests pass acceptance criteria?
Step 5: Design Validation
โโโ Confirm device meets user needs in actual use conditions
Verification: Validation report approved?
Step 6: Design Transfer
โโโ Release to production with DMR complete
Verification: Transfer checklist complete?
CAPA Process (820.100)
- Identify: Document nonconformity or potential problem
- Investigate: Perform root cause analysis (5 Whys, Fishbone)
- Plan: Define corrective/preventive actions
- Implement: Execute actions, update documentation
- Verify: Confirm implementation complete
- Effectiveness: Monitor for recurrence (30-90 days)
- Close: Management approval and closure
Reference: See qsr_compliance_requirements.md for detailed QSR implementation guidance.
HIPAA for Medical Devices
HIPAA requirements for devices that create, store, transmit, or access Protected Health Information (PHI).
Applicability
| Device Type | HIPAA Applies |
|---|---|
| Standalone diagnostic (no data transmission) | No |
| Connected device transmitting patient data | Yes |
| Device with EHR integration | Yes |
| SaMD storing patient information | Yes |
| Wellness app (no diagnosis) | Only if stores PHI |
Required Safeguards
Administrative (ยง164.308)
โโโ Security officer designation
โโโ Risk analysis and management
โโโ Workforce training
โโโ Incident response procedures
โโโ Business associate agreements
Physical (ยง164.310)
โโโ Facility access controls
โโโ Workstation security
โโโ Device disposal procedures
Technical (ยง164.312)
โโโ Access control (unique IDs, auto-logoff)
โโโ Audit controls (logging)
โโโ Integrity controls (checksums, hashes)
โโโ Authentication (MFA recommended)
โโโ Transmission security (TLS 1.2+)
Risk Assessment Steps
- Inventory all systems handling ePHI
- Document data flows (collection, storage, transmission)
- Identify threats and vulnerabilities
- Assess likelihood and impact
- Determine risk levels
- Implement controls
- Document residual risk
Reference: See hipaa_compliance_framework.md for implementation checklists and BAA templates.
Device Cybersecurity
FDA cybersecurity requirements for connected medical devices.
Premarket Requirements
| Element | Description |
|---|---|
| Threat Model | STRIDE analysis, attack trees, trust boundaries |
| Security Controls | Authentication, encryption, access control |
| SBOM | Software Bill of Materials (CycloneDX or SPDX) |
| Security Testing | Penetration testing, vulnerability scanning |
| Vulnerability Plan | Disclosure process, patch management |
Device Tier Classification
Tier 1 (Higher Risk):
- Connects to network/internet
- Cybersecurity incident could cause patient harm
Tier 2 (Standard Risk):
- All other connected devices
Postmarket Obligations
- Monitor NVD and ICS-CERT for vulnerabilities
- Assess applicability to device components
- Develop and test patches
- Communicate with customers
- Report to FDA per guidance
Coordinated Vulnerability Disclosure
Researcher Report
โ
Acknowledgment (48 hours)
โ
Initial Assessment (5 days)
โ
Fix Development
โ
Coordinated Public Disclosure
Reference: See device_cybersecurity_guidance.md for SBOM format examples and threat modeling templates.
Resources
scripts/
| Script | Purpose |
|---|---|
fda_submission_tracker.py |
Track 510(k)/PMA/De Novo submission milestones and timelines |
qsr_compliance_checker.py |
Assess 21 CFR 820 compliance against project documentation |
hipaa_risk_assessment.py |
Evaluate HIPAA safeguards in medical device software |
references/
| File | Content |
|---|---|
fda_submission_guide.md |
510(k), De Novo, PMA submission requirements and checklists |
qsr_compliance_requirements.md |
21 CFR 820 implementation guide with templates |
hipaa_compliance_framework.md |
HIPAA Security Rule safeguards and BAA requirements |
device_cybersecurity_guidance.md |
FDA cybersecurity requirements, SBOM, threat modeling |
fda_capa_requirements.md |
CAPA process, root cause analysis, effectiveness verification |
Usage Examples
# Track FDA submission status
python scripts/fda_submission_tracker.py /path/to/project --type 510k
# Assess QSR compliance
python scripts/qsr_compliance_checker.py /path/to/project --section 820.30
# Run HIPAA risk assessment
python scripts/hipaa_risk_assessment.py /path/to/project --category technical